Digital Type Single Axis Tilt Sensor
Introduction
ER-TS-3166DI Digital Single Axis Tilt Meter is designed for industrial field control field. It has a built-in high-precision 16bit A/D converter and an N-order filtering algorithm to measure the tilt and pitching angle of the sensor output relative to the horizontal plane. The output interfaces RS232, RS485, RS422, TTL, PWM, CAN, MODBUS bus are available for selection.
The product is equipped with a high-precision digital sensor, which can correct the temperature drift of the sensor according to the monitoring temperature change of the built-in temperature sensor to ensure the repeatability of the product in low and high temperature environments. The corresponding output frequency is 100Hz. The finished product has reliable and stable performance, good scalability, and a variety of output options, which are suitable for various industrial control environments.
Features
Single axis tilt monitoring
Full range accuracy 0.01°, resolution 0.001°
Output frequency 5~100HZ (optional)
Wide voltage input DC 9~36 (5V can be customized)
Wide temperature working -40~+85℃
Measuring range: 0~±180°(optional)
High vibration resistance >20000g
Baud rate 2400~115200 (adjustable)
IP67 protection
Output RS232/RS485/TTL/MODBUS (optional)
Small volume (90*40*27mm) (customizable)
Applications
High voltage wire tower pole monitoring
Satellite solar antenna positioning
AGV trolley
Mining machinery, oil logging equipment
Medical equipment
Tripod head levelling
Hydraulic lifting platform
Inclination monitoring
Angle control of various construction machinery
Inspection of bridges and dams
Specifications
Parameter | Condition | ER-TS-3166DI-10 | ER-TS-3166DI-30 | ER-TS-3166DI-60 | ER-TS-3166DI-90 | Unit |
Measuring range | / | ±10 | ±30 | ±60 | ±90 | ° |
Measurement axis | / | X | X | X | X | / |
Zero temperature drift | -40~85° | ±0.008 | ±0.008 | ±0.008 | ±0.008 | °/℃ |
Sensitivity temperature coefficient | -40~85° | ≤100 | ≤100 | ≤100 | ≤100 | ppm/℃ |
Frequency response | DC response | 100 | 100 | 100 | 100 | Hz |
Resolution | / | 0.001 | 0.001 | 0.001 | 0.001 | ° |
Accuracy | -40~85℃ | 0.01 | 0.02 | 0.03 | 0.05 | ° |
Long-term stability | -40~85℃ | <0.013 | <0.022 | <0.031 | <0.054 | ° |
Power on start time | / | 0.2 | 0.2 | 0.2 | 0.2 | s |
Response time | / | 0.01 | 0.01 | 0.01 | 0.01 | s |
Rate | 5Hz output, 15Hz, 35Hz, 50Hz can set (RS485 without this function) | |||||
Output signal | RS232/RS485/RS422/TTL/PWM/CAN/MODBUS | |||||
Average working time | ≥45000 hours/time | |||||
Impact resistant | 20000g, 0.5ms, 3 times/axis | |||||
Shock resistant | 10grms, 10~1000Hz | |||||
Insulation resistance | ≥100MΩ | |||||
Waterproof level | IP67 | |||||
Cable | Standard 1.5 m length, wear resistance, oil proof, wide temperature, shielding cable 4*0.3mm² | |||||
Weight | 150g (excluding boxes) |
Application Techniques
1.The Difference between Tilt Sensor and Gyro Sensor
3.How to install the tilt sensor?
4.What are Tilt Switches and Tilt Sensors?
5.How to Use the Tilt Sensor and How to Install It?
6.Do you Know the Working Principle of Inclinometer ?