Digital Output Single Axis Tilt Sensor
Introduction
ER-TS-4156DI digital single axis tilt meter is a new generation of digital small-volume MEMS tilt meter, built-in dual-channel earth gravity tilt unit, which measures static gravity acceleration and converts it into tilt change. Thus the sensor output can be measured with respect to the horizontal plane tilt and pitch angle. The output mode has RS232, RS485 or TTL, MODBUS level interface to choose from. Due to the built-in MCU control system, the output linearity of the sensor has been corrected twice to make up for the loss of accuracy caused by the lack of analog correction.
The product adopts non-contact measurement of the original quantity, which can output the current attitude and inclination in real time. The operation is simple, and there is no need to retrieve the two sides of the change. It can resist external electromagnetic interference and adapt to harsh industrial environment for long-term work, so it is an ideal choice for industrial automation control and platform attitude measurement.
Features
Single axis tilt monitoring
Full range accuracy 0.1°, resolution 0.01°
Industrial design
Wide voltage input DC 9~36V (5V can be customized)
Wide temperature working -40~+85℃
Measuring range: 0~±180° (optional)
High vibration resistance >3500g
Baud rate 2400~115200 adjustable
IP67 protection
Output: RS232/RS485/TTL/MODBUS (optional)
Small volume (90*40*27mm) (customizable)
Applications
High voltage power line tower pole monitoring
Satellite solar antenna positioning
Aerial work vehicle
Mining machinery, oil logging equipment
Medical equipment
Tripod head levelling
Hydraulic lifting platform
Tilt based monitoring
Various construction machinery angle control
Inspection of bridges and dams
Specifications
Parameters | Conditions | ER-TS-4156DI-10 | ER-TS-4156DI-30 | ER-TS-4156DI-60 | ER-TS-4156DI-90 | Unit |
Measuring range | / | ±10 | ±30 | ±60 | ±90 | ° |
Measuring axis | / | X | X | X | X | / |
Zero temperature drift | -40~85° | ±0.01 | ±0.01 | ±0.01 | ±0.01 | °/℃ |
Sensitivity temperature coefficient | -40~85° | ≤150 | ≤150 | ≤150 | ≤150 | ppm/℃ |
Frequency response | DC response | 100 | 100 | 100 | 100 | Hz |
Resolution | Bandwidth 5Hz | 0.01 | 0.01 | 0.01 | 0.01 | ° |
Accuracy | -40~85℃ | 0.1 | 0.1 | 0.1 | 0.1 | ° |
Long term stability | -40~85℃ | <0.12 | ° | |||
Power on time | / | 0.2 | 0.2 | 0.2 | 0.2 | s |
Response time | / | 0.01 | 0.01 | 0.01 | 0.01 | s |
Rate | 5Hz output, 15Hz, 35Hz, 50Hz, 100Hz can be set (RS485 does not have this function) | |||||
Output signal | RS232/RS485/RS422/TTL/PWM/CAN/MODBUS | |||||
Average failure-free work | ≥55000 hours/time | |||||
Shock resistance | 3500g, 0.5ms, 3 times/axis | |||||
Anti-vibration | 10grms, 10~1000Hz | |||||
Insulation Resistance | ≥100MΩ | |||||
Waterproof level | IP67 | |||||
Cables | Standard 1.5M length, wearproof, grease proofing、wide temperature, Shielded cables6*0.2mm² | |||||
Weight | 145g (without packing box) |