ER-PS-SW Programmable AC Power Source
Introduction
ER-PS-SW series Programmable AC Power Sources have the ability to simulate the AC voltage and frequency used in all countries. They are excellent instruments for R&D, design production testing/evaluation, and QA verification. In addition, the frequency range covers 500 Hz, making these products ideal for commercial and defense avionics applications.
The ER-PS-SW series delivers maximum rated power for any adjustable output voltage up to 300Vac (L-N)/520Vac (L-L )for 3 phase units, and at any adjustable frequency between 40Hz to 500 Hz.
It integrates IGBT made by Mitsubishi, Siemens, and Infineon, and combines microprocessor and ARM &DSP control design together for quick response and higher reliability and parallel operation.
Features
10 memory locations for easy test setup and recall
Double protection with hardware and software
Free instrument control software available
Simulate transient conditions
Programmable starting, voltage and current limit
LCD to monitor voltage, current, frequency, power and power factor
Built-in RS232, RS485, communication port, suitable for remote monitoring
Capable for each phase unbalance loads
Specifications
Capacity: 1KVA to 450KVA
Overload: 110% 15Mins, 125% 300s, 150% 30s
Input voltage
1 phase 120V+/-20%, 1 phase 220V+/-20%, 3 x127V/220V+/-20%
3 x220V/380V+/-20% or as per your specific requirement (select one individual voltage)
Frequency: 0-70Hz
Power factor:
≥0.8 (standard type)
≥0.9 (12-pulse type, option item)
Output voltage
1 phase 10-150V/20-300V adjusted
3 phase 17-260V/34-520V adjusted (L-L)
(Set your desired voltage)
Current: 0-Limit (set your desired current)
Frequency: 50Hz/60Hz/400hz/40Hz-500Hz
Voltage regulation: +/-1%≥100V
Frequency regulation: +/-0.1%
Crest: 1.414+/-0.1
Distortion: THD<3%@ linear load≥100V
Phase Shift:
120°+/-1°(no load/balance load)
120°+/-3°(33% unbalance load)
120°+/-4°(100% unbalance load)
Protection
Over/under voltage
Over current, overload
Over temperature, short circuit
Voltage difference between each phase<3V
Additional output contactor (option item)
Display: Voltage, current, frequency, power/PF
Working condition
Temperature: -10 to 40℃
Humidity: 10-95%
Noise: <65dB within 1 meter
IP22/IP32
Altitude<1800m
Reliability & Efficiency
Mean Time Between Failure (MTBF) 50,000H
Mean Time to Restoration (MTTR)<30 min
Overall efficiency≥85%
Standards
EN61010
IEC62321
EN61326
EN62040-1-1
Application Techniques
1.What is the Device Interface Definition of MEMS North Seeker
2.What Performance is the FOG sensor in FOG North Finder
3.Where are MEMS Gyroscopes Used?
4.Research Background and Current Status of MEMS IMU
5.How do parameters affect the performance of the quartz accelerometer?
6.Background and Development Status of MEMS Inertial Sensors