ER-PS-50W series stabilized frequency stabilizer/AC Power Supply adopts rectification and inverter technology, which can convert unstable power from +/-30% variable voltage to a stable state of galvanically isolated single-phase or three-phase power supply.
The ER-PS-50W series is to prevent sensitive electronic/heavy-load electrical equipment from being damaged during unstable grid/generator power supply, such as flickering, power failure, etc. It integrates Mitsubishi and Siemens IGBTs, and combines analog signals to control the design to achieve compact size and higher reliability. It is widely used in factory manufacturing, technical research and household appliances.
Features
High reliability and availability
Galvanically isolated, low harmonic distortion
Isolated output transformer, suit for any unbalance loads.
Every single phase can be used independently
Thoroughly proven advanced SPWM and IGBT technology
Pure sine wave, sinusoidal output
Better overload capacity
Display real-time data: voltage, current, frequency and power
ER-PS-50W series power supply single units are available with the following capacities:
Single phase output: (Select one individual KVA)
1kva, 2kva, 3kva, 5kva,10kva,15kva, 20kva, 30kva, 45kva, 60kva, 100kva,150kva, 200kva
3phase output: (Select one individual KVA)
1kva, 3kva, 6kva, 10kva, 15kva, 20kva, 30kva, 45kva, 60kva, 100kva, 150kva, 200kva, 300kva, 400kva, 500kva, 600kva, 800kva, 1000kva, 1500kva, 2000kva
Specifications
Capacity
1KVA to 2000KVA
Input Voltage: 1 phase
120v+/-30%(80v-150v),
1 phase 220v+/-30%(160v-280v) or 3 phase 380v+/-30%(265v-495v) or as per your specific requirement
Frequency: 30hz-80hz
Power Factor
≥0.8 (Standard Type)
≥0.9 (12-pulse Type, option item)
Output Voltage: 1 phase 120V, 1 phase 220V
Or 3x220V/380V, 3x240V/415V
Or as per your specific requirement
Frequency: 50Hz or 60Hz
Voltage regulation: +/-1%
Frequency regulation: +/-0.1%
Crest: 1.414+/-0.1
Distortion: clean sine wave THD<3%@Linear loads
Overload
110% 15Mins, 120% shut down
Protection
Over/under voltage
Over current, over load
Over temperature, short circuit
Voltage difference between each phase <3V
Additional output contactor (Option item)
Display LED: voltage, current, frequency, power/PF
Working condition
Temperature: -10 to 40℃
Humidity: 10-95%
Noise: <65dB within 1 meter
IP22/IP32
Altitude <1800m
Reliability & Efficiency
Mean time between failure (MTBF) 50,000H
Mean time to restoration (MTTR) <30 min
Overall efficiency ≥80%
Standards
EN61010
EC62321
EN61326
EN62040-1-1
Application Techniques
1.What is the Device Interface Definition of MEMS North Seeker
2.What Performance is the FOG sensor in FOG North Finder
3.Where are MEMS Gyroscopes Used?
4.Research Background and Current Status of MEMS IMU
5.How do parameters affect the performance of the quartz accelerometer?
6.Background and Development Status of MEMS Inertial Sensors