ER-QA-03A High Performance Quartz Accelerometer
Introduction
ER-QA-03A High Performance Quartz Accelerometer with high reliability is mainly used in inertial measurement and test systems in the aerospace and aviation fields. It can carry out static test and dynamic test, which is a standard vibration sensor.
Features
The high performance quartz flexible accelerometer uses high-quality quartz crystals to achieve high precision acceleration measurement with extremely high reliability and stability. Its special flexible construction enables it to adapt to high acceleration applications under various environmental conditions, such as high temperature, high pressure and high vibration environments.
Application
In addition to being widely used in aerospace and military fields, high performance quartz flexible accelerometers are also widely used in automotive, medical and scientific research fields. In the field of scientific research, they can be used to study earthquakes, crustal movements, cosmology, and microgravity environments.
Specifications
No. | Parameters | ER-QA-03A1 | ER-QA-03A2 | ER-QA-03A3 | Unit |
1 | Range | ±50 | ±50 | ±50 | g |
2 | Threshold/Resolution | 5 | 5 | 5 | μg |
3 | Bias | ≤ (±3) | ≤ (±5) | ≤ (±7) | mg |
4 | Scale factor | 1.3±0.2 | 1.3±0.2 | 1.3±0.2 | mA/g |
5 | Class II non-linearity | ≤ (±20) | ≤ (±30) | ≤ (±30) | μg /g2 |
6 | Bias repeatability | ≤10 | ≤30 | ≤50 | μg |
7 | Scale factor repeatability | ≤15 | ≤30 | ≤50 | ppm |
8 | Class II non-linearity repeatability | ≤ (±10) | ≤ (±20) | ≤ (±30) | μg /g2 |
9 | Bias temp coefficient | ≤ (±10) | ≤ (±30) | ≤ (±50) | μg/℃ |
10 | Scale factor temp coefficient | ≤ (±20) | ≤ (±30) | ≤ (±50) | ppm /℃ |
11 | Noise | ≤5 | ≤8.4 | ≤8.4 | mv |
12 | Natural frequency | 400~800 | 400~800 | 400~800 | Hz |
13 | Bandwidth | 800~2500 | 800~2500 | 800~2500 | Hz |
14 | Vibration | 6g (20-2000Hz) | |||
15 | Shock | 100g, 5ms, 1/2sin | |||
16 | Operating temperature | -40~+80 | -40~+80 | -40~+80 | ℃ |
17 | Temperature range | -60~+120 | -60~+120 | -60~+120 | ℃ |
18 | Power voltage | ±12~±15 | ±12~±15 | ±12~±15 | V |
19 | Current | ≤(±20) | ≤(±20) | ≤(±20) | mA |
20 | Temp. sensor | Yes and no two type | |||
21 | Size | Ф25.4X30 | Ф25.4X30 | Ф25.4X30 | mm |
22 | Weight | ≤80 | ≤80 | ≤80 | g |
Install dimension
Application Techniques
1.Methods to Maintain the Long-Term Performance of Quartz Flexure Accelerometers
2.How to Improve the Impact Resistance of Quartz Accelerometer
3.Study on the Stability of Quartz Accelerometer Head
4.What is the Quartz Accelerometer Digital Closed Loop Servo Circuit?
5.MEMS Accelerometer Packaging Technology
6.Calibration Method of Accelerometer